东莞市永雄氙灯老化试验箱有限公司欢迎您!

RSS订阅 | 收藏本站 | 网站地图

氙灯老化试验箱

定制非标测试设备通过ISO、SGS、TUV、CE认证企业
全国免费服务热线134 1223 4013

您是否在搜: 皮革台式氙灯老化试验 非标定制氙灯耐气候试 风冷式氙灯耐气候试验 红外线氙灯老化试验箱

当前位置: 主页 > 新闻资讯 > 行业新闻 > 高低温试验箱FLTM-BO-116-01标准测试要求

高低温试验箱FLTM-BO-116-01标准测试要求

发布时间:2018-11-30 10:55    点击数:    【

本页面标准信息均来源于网络收集,或由参与标准制定的供应商提供,只作为参考使用,为确保测试结果的准确性、节省您的时间,如需FLTM BO 116-01_2007标准详细信息或FLTM BO 116-01_2007具体测试方法,欢迎与我们技术人员联系或给我们留言,我们将为您相关的技术支持。

 

FLTM BO 116-01_2007标准介绍

FLTM-BO-116-01标准简介

FLTM-BO-116-01 汽车内饰材料暴晒试验标准:水冷式氙弧灯气候试验箱方法

FLTM  BO 116-01_2007标准英文版

EXPOSURE OF INTERIOR TRIM MATERIALS IN A CONTROLLED IRRADIANCE

WATER COOLED XENON-ARC APPARATUS

Application

This procedure is used to determine the effects of simulated weather on interior trim materials using a controlled irradiance water cooled xenon-arc Weather-Ometer® with an auxiliary lantern and filters.

Apparatus Required

Operating Filter

335 nm long pass filters (SF-5 filters) or equivalent provided the transmission spectrum is within 95% of the SF-5 filter transmission at all wavelengths. The filters are reversible unless otherwise marked by a coating or etching.

Dimensions for the Ci 5000 series Weather-Ometer®:

339 mm +/- 0.13 mm x 70 mm +/- 0.13 mm x 3 mm +/- 0.52 mm

Dimensions for the Ci 35A, Ci 65A & Ci 4000 Weather-Ometer®:

220 mm +/- 0.13 mm x 70 mm +/- 0.13 mm x 3 mm +/- 0.52 mm

Lamp Sensor Irradiance Filter

420 nm Irradiance Filter

Available from:

Atlas Material Testing Technology LLC

4114 Ravenswood Ave.

Chicago, IL 60613 USA

Calibration Lamp

The calibration lamp must be calibrated to 420 nm with the lantern assembly removed.

Available from:

Atlas Material Testing Technology LLC

4114 Ravenswood Ave.

Chicago, IL 60613 USA

Sample & Test Conditions

Sample Conditioning

All test values indicated herein are based on material conditioned in a controlled atmosphere of 21 +/-2 °C and 50 +/- 5% relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified.

Test Conditions

Testing conditions such as black panel temperature, dry bulb temperature, humidity, light cycle times and dark cycle times are equivalent to those outlined in SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components Using a Controlled Irradiance Xenon-Arc Apparatus, Table 1,Section 6.1.5.

Place the 335 nm long pass filters (SF-5 filters) or equivalent into the auxiliary lantern. Orient thelantern around the xenon-arc lamp assembly which is equipped with the Quartz/Type "S" Borosilicate filtered xenon-arc lamp source as outlined in SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components Using a Controlled Irradiance Xenon-Arc Apparatus, Apparatus Set-Up, Section 6.

Exposures are monitored based on measured light at 1.06 W/m2 -/nm@420 nm SAE J2412 –Accelerated Exposure of Automotive Interior Trim Components Using a Controlled Irradiance XenonArc Apparatus, Table 1.

Calibration

Equipment Calibration

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components Using a Controlled Irradiance Xenon-Arc Apparatus, Appendix A, Section A.3 and Appendix B.

Maintenance

Equipment Maintenance

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components Using a Controlled Irradiance Xenon-Arc Apparatus, Appendix A.

Note: SF-5 auxiliary filters should be cleaned at every lamp calibration period or more frequent if necessary.

SF-5 filters and the 420 nm interference filter should be changed per the manufacturer's recommendations/or within 13,000 hours of use.

Exposure

Sample Exposure

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components Using a Controlled Irradiance Xenon-Arc Apparatus, Test Procedure, Section 7.

Evaluation & Reporting

Sample Evaluation and Exposure Report

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components Using a Controlled Irradiance Xenon-Arc Apparatus, Evaluating and Reporting, Section 8 and Exposure Report, Section 9.

AATCC Gray Scale, 10 Step, According to AATCC Evaluation Procedure 1/ISO 105-A02 for Evaluation of Color Change.

Upon request measure the gloss with a 60° glossmeter (or as specified in the applicable Engineering Standard) according to FLTM BI 110-01. Record the unexposed and exposed gloss.

Chemicals, materials, parts and equipment referenced in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities.

 

▼FLTM BO 116-01_2007第三方检测机构

以上标准信息来自互联网搜索整理,如需了解完整的FLTM BO 116-01_2007的信息或FLTM BO 116-01_2007标准解读,欢迎详询。

 

永雄仪器本文来源:未知    责任编辑:admin